CAVI TIPO “Li-YCY-P”
A COPPIE SCHERMATI A TRECCIA

IMPIEGO: Cavi schermati per segnali e trasmissione dati per
applicazioni in elettronica ed informatica, efficaci contro le interferenze
elettromagnetiche ed atti ad offrire una protezione contro
influenze capacitive dovute a campi elettrici.

CABLES TYPE “Li-YCY-P”
TWISTED PAIRS, TINNED COPPER BRAID SHIELD

STANDARD USE: Signal and data transmission shielded cables
for electronics and information technology applications,
effective against electromagnetic interferences and suited to offer
protection against capacitive influences due to electric fields.

CARATTERISTICHE TECNICHE

 

TECHNICAL FEATURES

CONDUTTORI:
Flessibili in rame rosso
sec. CEI 20-29 (IEC 228) Cl. 5, VDE 0295 Cl. 5, NF C32-013
(0,34 mm2 : VDE 0295 Cl.2)
CONDUCTORS:
Flexible bare copper conductors
CEI 20-29 (IEC 228) Cl. 5, VDE 0295 Cl. 5,
NF C32-013 Ref. (0,34 mm2 : VDE 0295 Cl.2)
ISOLANTE:
Polivinilcloruro (PVC)
Sec. CEI 20-11 Cl. R2, VDE 0207 Cl. YI2
Codici colori: a norma DIN 47100
INSULATION:
Polyvinylchloride (PVC)
CEI 20-11 Cl. R2, VDE 0207 Cl. YI2 Ref.
Colour code according to DIN 47100
SEPARATORE:
Nastro di poliestere
ASSEMBLING:
Polyester tape helically wound
SCHERMATURA:
A treccia di rame stagnato
Cordina di continuità a richiesta
SHIELD:
Tinned copper braid
On request with drain wire
GUAINA ESTERNA:
Polivinilcloruro (PVC)
Sec. CEI 20-20 Cl. TM2, VDE 0207 Cl. YM2
colore: grigio (diverso a richiesta)
JACKET:
Polyvinylchloride (PVC)
CEI 20-20 Cl. TM2, VDE 0207 Cl. YM2 Ref.
colour: grey or on request
RESISTENZA ELETTRICA DEI CONDUTTORI:
0,14 mm2: <148 Ohm/Km
0,25 mm2: <79 Ohm/Km
0,34 mm2: <55 Ohm/Km
0,50 mm2: <39 Ohm/Km
0,75 mm2: <26 Ohm/Km
1mm2: <19,5 Ohm/Km
ELECTRICAL CONDUCTOR RESISTANCE:
0,14 mm2: <148 Ohm/Km
0,25 mm2: <79 Ohm/Km
0,34 mm2: <55 Ohm/Km
0,50 mm2: <39 Ohm/Km
0,75 mm2: <26 Ohm/Km
1mm2: <19,5 Ohm/Km
TEMPERATURA DI ESERCIZIO:
posa fissa: -25°C + 70°C
posa mobile: -15°C + 70°C
WORKING TEMPERATURE:
fixed installation: -25°C
flexing: -15°C + 70°C
RAGGIO DI CURVATURA:
15 volte il diametro del cavo
BENDING RADIUS:
15 times overall diameter of cable
TENSIONE DI ESERCIZIO:
250 V
WORKING VOLTAGE:
250 V
TENSIONE DI PROVA:
1500 V
TEST VOLTAGE:
1500 V
PROVA N.P. FIAMMA:
Standard: sec. CEI 20-35 (IEC 332.1)
A richiesta: sec. CEI 20-22 II (IEC 332.3A)
FLAME RETARDANT TEST:
Standard: CEI 20-35 (IEC 332.1) Ref.
On request: CEI 20-22 II (IEC 332.3A) Ref.
IMPEDENZA DI TRASFERIMENTO:
max 200 mohm/m (f<10MHz)
SURFACE TRANSFER IMPEDANCE:
max 200 mohm/m (f<10MHz)
CAPACITA’ DI LAVORO:
cond/cond: 120 nF/km (nom.)
cond/sch: 180 nF/km (nom.)
CAPACITANCE:
cond/cond: 120 nF/km (nom.)
cond/shield: 180 nF/km (nom.)

Download technical features and cable's typology (PDF)

Download Adobe Reader