Elettronica Conduttori - Cavi elettrici speciali

ISO/TS certified company

<

PVC Shielded Cables

IMPIEGO: Shielded power and control cables for dynamic applications in industrial drag chains, with small external dimensions, high flexibility and good resistance to industrial oils.

Technical Features

  • Conductors Extraflexible stranded bare copper (Cu-ETP1) CEI 20-29 cl.6, VDE 0295 cl.6, EN 60228, IEC 60228 ref. Cross sect. area (mm2): from 0,14 to 16.
  • Insulation Polyvinylchloride (PVC) CEI 20-11 cl. R2, EN 50363 ref. Colour code: up to 0,35 mm2: DIN 47100
    from 0,50 mm2: Black numbered with or without Yellow/Green
  • Overall Shield Tinned copper braid. Optical coverage: ≥ 85%
  • Assembling Non woven tape.
  • Jacket Flame retardant and oil resistant Polyvinylchloride. Colour code: Grey Ral 7001
    Green Ral 6018 DESINA
    Orange Ral 2003 DESINA (power lines) or Black (other colours on request)
  • Operating Voltage up to 0,35 mm2: 300 V from 0,50 to 1 mm2: 300 V (UL); 300/500 V from 1,5 mm2: 1000 V (UL); 0,6/1 kV
  • Test Voltage up to 0,35 mm2: 2000 V from 0,50 to 1 mm2: 3000 V from 1,5 mm2: 4000 V
  • Operating Temperature Dynamic application: -15°C +80°C
  • Bending radius 7,5 times overall diameter of cable.
  • Maximun Speed 180 m/min
  • Maximun Acceleration 10 m/sec2
  • Flex Life from 3 to 6 million of motions (bending radius 10 times overall diameter of cable)
  • Flame retardant test; No Flame propagation test; CEI 20-35/1-2, EN 60332-1-2, IEC 60332-1-2. CEI 20-22/2, EN 60332-3-22 CAT.A, IEC 60332-3-22 CAT.A.
  • K2_EC_EXTRAF_ULCSAPVC up to 1,0 mm2: AWM STYLE 2464 – CSA I/II A/B 80°C 300 V FT1 from 1,5 mm2: AWM STYLE 2570 – CSA I/II A/B 80°C 1000 V FT1
  • Optional Jacket Matt flame retardant Polyurethane blend, oil resistant.
  • Polyurethane blend jacket UL-CSA Approval (E235078) up to 1,0 mm2: AWM STYLE 20233 or 20549 – CSA I/II A/B 80°C 300 V FT1 from 1,5 mm2: AWM STYLE 20234 or 21223 – CSA I/II A/B 80°C 1000 V FT1