Elettronica Conduttori - Cavi elettrici speciali

ISO/TS certified company

<

Measuring System Cables Halogen Free

STANDARD USE: Cables for interconnecting Siemens®, Heidenhain® measuring system-encoder or equivalent systems, outstanding resistance to industrial oils and other chemical and mechanical agents, UL-CSA DESINA approval.

Technical Features

  • Conductors Flexible tinned copper (Cu-ETP1) UL 1581, CEI 20-29 cl.5, VDE 0295 cl.5, EN 60228, IEC 60228 ref.
  • Insulation Polyolefin
    Colour code: differently coloured
  • Inner Shield Single twisted pair or element: tinned copper helically wound Optical coverage: ≥ 85%
  • Overall Shield Tinned copper braid. Optical coverage: ≥ 85%.
  • Assembling Synthetic tape
  • Optional Assembling Non woven tape.
  • Jacket Low friction halogen free matt flame retardant Polyurethane, hydrolysis, microbial attack, abrasion, tear, oil resistant
    UL 1581 ref.
    Colour code: Green Ral 6018 DESINA (other colours on request)
  • Inner Jacket Polyolefin on the single shielded twisted pair colour: Black
  • Electrical Conductor Resistance 0,14 mm2: < 150,0 Ohm/Km
    0,25 mm2: < 91,0 Ohm/Km
    0,50 mm2: < 40,1 Ohm/Km
  • Operating Voltage 30 V
  • Test Voltage 1500 V
  • Operating Temperature -40°C + 80°C
  • Bending radius 10 times overall diameter of cable.
  • Flame retardant test; Non-Halogen Verification CEI 20-35/1-2, EN 60332-1-2, IEC 60332-1-2 UL 1581 cable flame test, FT1 test. < 0,5 % (CEI 20-37/2-1, CEI EN 50267-2-1, IEC 60754-1)
  • UL-CSA Approval (E235078) AWM Style 20236 80°C 30 V - CSA I/II A/B 80°C 30 V FT1 AWM Style 20554 80°C 30 V - CSA I/II A/B 80°C 30 V FT1

REQUEST INFORMATION

Measuring System Cables Halogen Free

Indicate the section and number of conductors of the cable.
Required field
Campo obbligatorio
Required field
Required field
Required field
Required field
refresh