Elettronica Conduttori - Cavi elettrici speciali

ISO/TS certified company

<

Bus cable for power, data, voice

STANDARD USE: Cables for power, control, audio and data

cavi-alimentazione

TECHNICAL FEATURES

CONDUCTORS
Stranded tinned copper conductors
CEI 20-29 cl.5 (IEC 228), VDE 0295 cl.5 ref.
INSULATION
Polyvinylchloride (PVC) lead free
CEI 20-20 Cl. R2 Ref.
ico-guainaesterna
SHIELD
Data twist pairs: Aluminium/polyester
tape helically wound, tinned copper drain wire
ico-schermatura
ASSEMBLING
Polyester tape helically wound
JACKET
Polyvinylchloride (PVC)
colour: blue or on request
ELECTRICAL CONDUCTOR RESISTANCE
0.25 mm2 : <78 Ohm/Km
0.50 mm2 : <39 Ohm/Km
1.5 mm2 : <13,7 Ohm/Km
WORKING TEMPERATURE
-15°C + 80°C
ico-raggiocurvatura
BENDING RADIUS
15 times overall diameter of cable
ico-freccia
WORKING VOLTAGE
Voltage: 300 V
Data: 50 V
ico-freccia2
TEST VOLTAGE
1500 V
ico-fuoco
FLAME RETARDANT TEST
Standard: sec. CEI 20-22 II (IEC 332.3A)
ico-info
SURFACE TRANSFER IMPEDANCE
max 200 mohm/m (f<10MHz)
ico-capacita
CAPACITANCE:
Coppie dati: < 170 pF/m
THE ABOVE MENTIONED CABLES CAN BE SUPPLIED
LSZH HALOGEN FREE
AND LOW CAPACITANCE DATA TWIST PAIRS

 

REQUEST INFORMATION

Indicate the section and number of conductors of the cable.
Required field
Campo obbligatorio
Required field
Required field
Required field
Required field
refresh
 

©2016 Elettronica Conduttori Srl - Via Brandizzo, 430 - 10088 Volpiano (TO) ITALY - Tel. +39.011.9884777 r.a. - Fax +39.­011.9885123
This email address is being protected from spambots. You need JavaScript enabled to view it. - This email address is being protected from spambots. You need JavaScript enabled to view it. - P.IVA 04050870015 - Credits - Cookie Policy