Elettronica Conduttori - Cavi elettrici speciali

ISO/TS certified company

<

Cables for Geophysic, seismic and enviromental analysis

IMPIEGO: Cables for geophysic and seismic applications, multicore or twisted pairs assembly.

cavi-speciali-geoelettrica

TECHNICAL FEATURES

CONDUCTORS
Stranded tinned copper conductors
INSULATION
Polyolefin
Colour code: according to DIN 47100
ico-rinforzo
MECHANICAL SUPPORT (ON REQUEST)
Central synthetic aramidic yarn element
ico-schermatura
ASSEMBLING (OPTIONAL)
Nonwowen tape helically wound
ico-guainaesterna
SHIELD (ON REQUEST)
Tinned copper braid
JACKET
Polyurethane hydrolisys, abrasion, tear, UV, oil resistant
colour: yellow (or on request)
ELECTRICAL CONDUCTOR RESISTANCE
28AWG ( 7x36AWG): < 237 Ohm/Km
22AWG (19x35AWG): < 55 Ohm/Km
20AWG (28x35AWG): < 40 Ohm/Km
18AWG (56x35AWG): < 20 Ohm/Km
WORKING TEMPERATURE
-40°C + 80°C
ico-raggiocurvatura
BENDING RADIUS
15 times overall diameter of cable
ico-freccia
WORKING VOLTAGE
300 V
ico-freccia2
TEST VOLTAGE
1500 V
ico-capacita
CAPACITANCE:
cond/cond (nominal): 50 pF/m/div>
ico-info
CHARACTERISTIC IMPEDANCE (TWISTED PAIR CABLES)
100 Ω (nominal)

 

REQUEST INFORMATION

Indicate the section and number of conductors of the cable.
Required field
Campo obbligatorio
Required field
Required field
Required field
Required field
refresh
 

©2016 Elettronica Conduttori Srl - Via Brandizzo, 430 - 10088 Volpiano (TO) ITALY - Tel. +39.011.9884777 r.a. - Fax +39.­011.9885123
This email address is being protected from spambots. You need JavaScript enabled to view it. - This email address is being protected from spambots. You need JavaScript enabled to view it. - P.IVA 04050870015 - Credits - Cookie Policy