Categories


Profibus PUR
STANDARD USE
Profibus low capacitance cables for industrial application in drag chains, with twisted pairs and double shield, outstanding resistance to industrial oils and other chemical and mechanical agents, UL-CSA approval.
Profibus DP – FMS L2, Profibus CAN, I-BUS.
Data sheet More infoTechnical details:

Conductors
Extraflexible stranded bare or tinned copper (Cu-ETP1) UL 1581, VDE 0295 cl.6 ref.
Insulation
Polyolefin.Twisted pair colour code: differently coloured.

Shield
Aluminized tape helically wound and tinned copper braid.Optical coverage braid:
≥ 60% standard
≥ 85% on request.

Assembling
Non woven tape.
Jacket
Low friction halogen free matt flame retardant Polyurethane, hydrolysis, microbial attack, abrasion, tear, oil resistant.Colour code: Violet Ral 4001.

Electrical Conductor Resistance
24AWG: < 94,2 Ohm/Km22AWG: < 59,4 Ohm/Km

Surface Transfer Impedance
Optical coverage braid shield ≥ 60%:max 50 mohm/m (f<10MHz).
Optical coverage braid shield ≥ 85%:
max 20 mohm/m (f<10MHz).

Operating Voltage
30 V
Operating Temperature
Dynamic application: -40°C +80°C
Bending radius
8 times overall diameter of cable.
Maximun Speed
200 m/min
Maximun Acceleration
10 m/sec2
Flame retardant test
CEI 20-35/1-2, EN 60332-1-2, IEC 60332-1-2
Non-Halogen Verification
< 0,5 % (CEI 20-37/2-1, CEI EN 50267-2-1, IEC 60754-1)
UL-CSA Approval (E235078)
Style 20236 80°C 30 V – CSA I/II A/B 80°C 30 V FT1
PROFIBUS L2 PUR EXTRAFLEX

Conductors
Extraflexible stranded bare copper 22AWG
Insulation
PolyolefinColour code: Red, Green

Jacket
PURColour code: Violet Ral 4001

Impedance
150 Ohm (nominal)
Capacitance
30 pF/m (nominal)
Use
For dynamic laying
PROFIBUS CAN PUR EXTRAFLEX

Conductors
Extraflexible stranded bare copper 24AWG
Insulation
PolyolefinColour code: according to DIN 47100

Jacket
PURColour code: Violet Ral 4001

Impedance
100-120 Ohm (nominal)
Capacitance
50 pF/m (nominal)
Use
For dynamic layingSISTEMA / SYSTEM | CODICE / CODE | FORMAZIONE / TYPE | Ø ESTERNO / OUTER Ø ±5% (mm) | PESO MEDIO / AVERAGE WEIGHT (kg/km) |
---|---|---|---|---|
PROFIBUS | (1x2x22AWG)ST/SN | 8,0 | 85 | |
PROFIBUS HYBRID | (1x2x22AWG)SN/ST+3G0,75 | 9,8 | 105 |