Categories
![](https://www.elettronicaconduttori.com/wp-content/uploads/2020/08/Ethernet-Automotive.png)
Ethernet Automotive Cat. 5E UN/ECE R118
STANDARD USE
S-FTP cat. 5E double shielded cables,
RJ45 connectable, for interconnection
of Automotive electronic appliances, with UN/ECE R118 approval.
Cables with drain wire.
Data sheet More infoTechnical details:
![](https://www.elettronicaconduttori.com/wp-content/uploads/2018/03/icon-conduttori.png)
Conductors
Flexible stranded bare copper (Cu-ETP1) conductors ISO 6722,FCA Procurement specification 91116/01.
![](https://www.elettronicaconduttori.com/wp-content/uploads/2018/03/icon-isolante.png)
Insulation
Special flame retardant Polyolefin compound, PVC free, “Lead free”, temperature rating up to 125°C (class T3, ISO 6722 class C) oil and fuel resistant ISO 6722, FCA Procurement specification 91116/01.4 pairs colour code cable:
(White/Blue, Blue), (White/Orange, Orange)(White/Green, Green),(White/Brown, Brown)
![](https://www.elettronicaconduttori.com/wp-content/uploads/2018/03/icon-separatore.png)
First Shield
Aluminium/Polyester tape with aluminium side in direct contact with braid and drain wire.![](https://www.elettronicaconduttori.com/wp-content/uploads/2018/03/icon-schermaturatotale.png)
Overall Shield
Tinned copper braid.Optical coverage braid: ≥ 85%.
![](https://www.elettronicaconduttori.com/wp-content/uploads/2018/03/icon-shield.png)
Jacket
Special flame retardant Polyolefin compound, PVC free, “Lead free”, temperature rating up to 125°C (class T3, ISO 14572 class C) oil and fuel resistant ISO 14572, FCA Procurement specification 91116/01.Colour code: Black.
![](https://www.elettronicaconduttori.com/wp-content/uploads/2018/03/icon-resistenzaconduttori.png)
Electrical Conductor Resistance
26AWG: 150 Ohm/Km![](https://www.elettronicaconduttori.com/wp-content/uploads/2018/03/icon-capacita-pair.png)
Nominal Pair Capacitance
50 pF/m![](https://www.elettronicaconduttori.com/wp-content/uploads/2018/03/icon-impedenzacaratteristica.png)
Characteristic Impedance
100 ± 15 Ohm (1 – 100 MHz)![](https://www.elettronicaconduttori.com/wp-content/uploads/2018/03/icon-velocitatrasmissione.png)
Transmission Rate
26AWG: 100 Mbit/s: up to 75 m![](https://www.elettronicaconduttori.com/wp-content/uploads/2018/03/icon-tensione-esercizio.png)
Operating Voltage
60 V![](https://www.elettronicaconduttori.com/wp-content/uploads/2018/03/icon-temp-esercizio.png)
Operating Temperature
-40°C +125°C![](https://www.elettronicaconduttori.com/wp-content/uploads/2018/03/icon-raggiocurvatura.png)
Bending radius
10 times overall diameter of cable.![](https://www.elettronicaconduttori.com/wp-content/uploads/2018/03/icon-provafiammauno.png)
Flame retardant test
ISO 6722ISO 14572
SISTEMA / SYSTEM | CODICE / CODE | FORMAZIONE / TYPE | Ø ESTERNO / OUTER Ø ±5% (mm) | PESO MEDIO / AVERAGE WEIGHT (kg/km) |
---|---|---|---|---|
MCWRS 262/0410-EC | (4x2x26AWG)SN-ST | 6,1 | 50 |