Categories
Technical details:
![](https://www.elettronicaconduttori.com/wp-content/uploads/2018/03/icon-conduttori.png)
Conductors
Stranded bare copper conductors.![](https://www.elettronicaconduttori.com/wp-content/uploads/2018/03/icon-isolante.png)
Insulation
Special flame retardant halogen free low smoke compound.Colour code: differently coloured.
![](https://www.elettronicaconduttori.com/wp-content/uploads/2018/03/icon-shield.png)
Jacket
Special flame retardant halogen free low smoke compound CEI 20-11, EN 50363-0 quality M1, VDE 0207 HM2.Colour: Grey or upon request
![](https://www.elettronicaconduttori.com/wp-content/uploads/2018/03/icon-coassiale.png)
Coaxial cable
Microcoaxial or RG-59.Microcoaxial 75 Ω:
Conductor: 7-stranded tinned copper conductor28AWG (7x36AWG).
Insulation: LSZH Foamed Polyethylene.
Shield:Bare copper braid.
Jacket:Non-contaminating special LSZH flame retardant compound.
RG-59 75 Ω:
Conductor:solid copperweld diam. 0,58 mm.
Insulation:LSZH Polyethylene
shield:Bare copper braid.
Jacket:Non-contaminating special LSZH flame retardant compound.
![](https://www.elettronicaconduttori.com/wp-content/uploads/2018/03/icon-temp-esercizio.png)
Operating temperature
-25°C +80°C(fixed lying)![](https://www.elettronicaconduttori.com/wp-content/uploads/2018/03/icon-curvatura.png)
Bending radius
10 times overall diameter of cable (fixed laying)![](https://www.elettronicaconduttori.com/wp-content/uploads/2018/03/icon-provafiammauno.png)
Flame retardant test
CEI 20-35/1-2, EN 60332-1-2, IEC 60332-1-2.![](https://www.elettronicaconduttori.com/wp-content/uploads/2018/03/icon-provafiammauno.png)
Non-halogen verification
< 0,5 % (CEI 20-37/2-1, CEI EN 50267-2-1, IEC 60754-1)![](https://www.elettronicaconduttori.com/wp-content/uploads/2018/03/icon-provafiammauno.png)
Corrosivity of combustion gas
pH: > 4,3 - Conductivity: < 10 μS/mm (CEI 20-37/2-2, CEI EN 50267-2-2, IEC 60754-2)![](https://www.elettronicaconduttori.com/wp-content/uploads/2018/03/icon-provafiammauno.png)
Smoke density
Transmission of light: > 70% (CEI 20-37/3-1, EN 61034-2)![](https://www.elettronicaconduttori.com/wp-content/uploads/2018/03/icon-provafiammauno.png)
Toxicity index
< 2 (CEI 20-37/4-0)![](https://www.elettronicaconduttori.com/wp-content/uploads/2018/03/icon-separatore.png)
Overall Schield
Aluminium/polyester tape helically wound with stranded bare copper drain wire.![](https://www.elettronicaconduttori.com/wp-content/uploads/2018/03/icon-schermaturatotale.png)
Overall shield
Bare copper braid.![](https://www.elettronicaconduttori.com/wp-content/uploads/2018/03/icon-schermaturatotale.png)
Armour
Zinc coated steel braidor stainless steel braid.