Technical details:

Conductors
Stranded bare copper conductors.
Insulation
Special flame retardant halogen free low smoke compound.Colour code: differently coloured.

Jacket
Special flame retardant halogen free low smoke compound CEI 20-11, EN 50363-0 quality M1, VDE 0207 HM2.Colour: Grey or upon request

Coaxial cable
Microcoaxial or RG-59.Microcoaxial 75 Ω:
Conductor: 7-stranded tinned copper conductor28AWG (7x36AWG).
Insulation: LSZH Foamed Polyethylene.
Shield:Bare copper braid.
Jacket:Non-contaminating special LSZH flame retardant compound.
RG-59 75 Ω:
Conductor:solid copperweld diam. 0,58 mm.
Insulation:LSZH Polyethylene
shield:Bare copper braid.
Jacket:Non-contaminating special LSZH flame retardant compound.

Operating temperature
-25°C +80°C(fixed lying)
Bending radius
10 times overall diameter of cable (fixed laying)
Flame retardant test
CEI 20-35/1-2, EN 60332-1-2, IEC 60332-1-2.
Non-halogen verification
< 0,5 % (CEI 20-37/2-1, CEI EN 50267-2-1, IEC 60754-1)
Corrosivity of combustion gas
pH: > 4,3 - Conductivity: < 10 μS/mm (CEI 20-37/2-2, CEI EN 50267-2-2, IEC 60754-2)
Smoke density
Transmission of light: > 70% (CEI 20-37/3-1, EN 61034-2)
Toxicity index
< 2 (CEI 20-37/4-0)
Overall Schield
Aluminium/polyester tape helically wound with stranded bare copper drain wire.
Overall shield
Bare copper braid.
Armour
Zinc coated steel braidor stainless steel braid.