PVC Shielded Cables

STANDARD USE

Shielded power and control cables for static applications in industrial environments, with small external dimensions, high flexibility and good resistance to industrial oils.

Data sheet
More info

Technical details:

Conductors

Flexible stranded bare copper (Cu-ETP1) CEI 20-29 cl.5, VDE 0295 cl.5, EN 60228, IEC 60228 ref.
Cross sect. area (mm2): from 0,14 to 16.

Insulation

Polyvinylchloride (PVC) CEI 20-11 cl. R2, EN 50363 ref.
Colour code:
up to 0,35 mm2 : DIN 47100.
from 0,50 mm2 : Black numbered with or without Yellow/Green.

Overall Shield

Tinned copper braid.
Optical coverage: ≥ 85%

Assembling

Polyester tape.

Jacket

Flame retardant and oil resistant Polyvinylchloride.
Colour code:
Grey Ral 7001
Green Ral 6018 DESINA
Orange Ral 2003 DESINA (power lines)
Black (other colours on request)

Operating Voltage

up to 0,35 mm2: 300 V
from 0,50 to 1 mm2: 300 V (UL); 300/500 V
from 1,5 mm2: 1000 V (UL); 0,6/1 kV



Test Voltage

up to 0,35 mm2: 2000 V
from 0,50 to 1 mm2: 3000 V
from 1,5 mm2: 4000 V

Operating Temperature

-30°C +80°C


Bending radius

10 times overall diameter of cable.

Flame retardant test

CEI 20-35/1-2, EN 60332-1-2, IEC 60332-1-2.

No Flame propagation test

CEI 20-22/2, EN 60332-3-22 CAT.A, IEC 60332-3-22 CAT.A.

Pvc jacket UL-CSA Approval (E235078)

up to 1,0 mm2:
AWM STYLE 2464 – CSA I/II A/B 80°C 300 V FT1
from 1,5 mm2:
AWM STYLE 2570 – CSA I/II A/B 80°C 1000 V FT1

Optional Jacket

Matt flame retardant Polyurethane blend, oil resistant.

Polyurethane blend jacket UL-CSA Approval (E235078)

up to 1,0 mm2:
AWM STYLE 20233 or 20549 – CSA I/II A/B 80°C 300 V FT1
from 1,5 mm2: